Radar water level

Radar water level sensor undergoes River Thames trial

British Environment Agency hydrologists have recently trialled a new radar water level sensor at a site by Molesey Lock on the River Thames near Hampton Court Palace. The sensor was installed during October 2008 and initial results indicate that significant time and cost savings are possible with the new technology.

Installation of OTT Meßtechnik Radar Level Sensors

Installation of OTT Meßtechnik Radar Level Sensors


Water level measurements are taken at the lock for onward transmission to the Environment Agency’s offices via PSTN telephone and inclusion in the British national archive. However, alarms are set for low and high water level so that the lock keeper can manage the river for the river users; many valuable floating homes are moored in the area. If the river gets too low these homes will bottom out which could cause considerable damage.

Prior to the installation of the radar sensor, data was provided by a shaft encoder that recorded water level in a specially constructed stilling well which had been installed approximately 300m upstream of the lock, on the other side of the river to the telemetry outstation. This meant that the data transfer cable had to pass under the river and Agency staff had to walk back and forth between the sensor and the outstation to set the head level for example.

The radar sensor was installed very close to the outstation which allows the Environment Agency to set the levels that the sensor is measuring more accurately in the outstation.

These sensors avoid the necessity for capital works to install a stilling well and can be installed quickly and simply.

The sensor scans every 30 seconds providing values for screen display on site. It also logs a reading every 15 minutes for transmission via the telemetry outstation.

They are ideal for contact-free water and liquid level monitoring in difficult to measure and remote locations or those which are subject to flooding. Simon Wills, Managing Director at OTT Hydrometry the company which supplied the sensor says, “This technology offers a number of extremely attractive features which make it suitable for a wide variety of applications. For example, it has a wide measurement range up to 35 metres with ± 1cm accuracy across the entire range and offers a number of communication options including RS232, RS484, SDI12, or 4-20 mA. Importantly, it employs pulse radar rather than a frequency modulated wave, which means that high levels of accuracy are still possible but power consumption is extremely low which means that the sensor can operate from a solar or wind powered battery system in almost any location.”

The Molesey Lock sensor is mains powered but the Environment Agency has recently purchased a further sensor and plans to install a solar powered station for comparison with a shaft encoder sensor.

Commenting on his experience with the radar sensor the Environment Agency’s Rikk Smith says, “We have been very pleased with this sensor because it was quick and easy to install and we have not had to touch it since it was installed over five months ago.”

Advertisements

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

%d bloggers like this: